Figure 3A. Dewar.
The cells shown in are shown in brackets at a. Stepped pressure-sensing tubes for cells B, C, and D are labeled bb’, cc’, and dd’ respectively. The steps are in thermal contact with liquid He4 refrigerant pot, f , at flange, e, and with liquid N2 pot g, at flange, h. Copper radiation shields are bolted to f at flange, e, and to g at flange, h. To minimize the thermomolecular pressure gradient without unduly increasing heat leaks, tubes W and cc’ increase in inside diameter from 0.133 cm to 0.583 cm at e, and to 2.49 cm at h. Tube dd’ increases from 0.266 to 1.85 at e, and to 4.89 cm at h
Figure 3B. A sectional view shows the details of reducing couplings which also serve as radiation shields in each of the vapor pressure-sensing tubes.
The couplings are soft soldered to flange, h.